Back to range

F381 SD card compatible Dynamic Force Processor with LCD Touch Panel Display
 

* Waveform comparison function (Sequential comparison of HI/LO limit set waveform and actual measurement waveform)
* Multi-hold function (HI/LO limit comparison is made by changing the type of hold function in each divided measurement segment)
* Standard equipped with displacement input (A 2-dimensional waveform comparison is possible by using both force and displacement inputs)
* Save measurement data and setting values in an SD card
* Easy parameter setting allowed by direct touch on touch panel
* Plus common and minus common shared, and Sink type / Source type selectable
* 4000 times/sec high-speed digital processing
 

F395

Dynamic Force processor of Real-time Waveform Processing Type

 

* Waveform comparison function with XY function
* Visibility and operability improved by application of the color LCD and touch panel
* Communication function with control of sampled waveform uploaded to PC by spreadsheet software
* High-speed digital circuit with processing capability of 4000 times/sec (max)
* 20 types of hold modes including Peak, Valley, Relative Maximum Value, Relative Minimum Value and Inflection Point are switchable by external signal.
 

F372

Digital Indicator of Color Graphic Display / Touch Panel Type

 

* Changes in physical quantity, that are recognizable only by numerical display, are displayed in waveform.
* Extensive Hold functions that enable holding an accurate point and OK/NG judgment function
* Double Hold that can perform two types of Hold simultaneously, Before Value Comparison and Relative Value Comparison functions are included.
* Easy and simple setting operation by directly touching touch panel
* Compact square DIN 96 size
* High-speed digital processing capability of 2000 times/sec
 

F377

Digital Indicator of Color Graphic Display/Touch Panel Type of Voltage/ Current Output Sensors

 

* Directly connectable to Voltage±10V, Current±20mA
* Changes in physical quantity, that are recognizable only by numerical display, are displayed in waveform.
* Extensive hold functions that enable holding an accurate point and OK/NG judgment function
* Double Hold that can perform two types of Hold simultaneously, Before Value Comparison and Relative Value Comparison functions are included.
* Compact square DIN 96 size
* High-speed digital processing capability of 2000 times/sec
 

F370&F371

Digital Indicator of Color Graphic Display/ Touch Panel Type

 

* Directly connectable to Voltage±10V, Current±20mA
* Changes in physical quantity, that are recognizable only by numerical display, are displayed in waveform.
* Extensive hold functions that enable holding an accurate point and OK/NG judgment function
* Double Hold that can perform two types of Hold simultaneously, Before Value Comparison and Relative Value Comparison functions are included.
* Compact square DIN 96 size
* High-speed digital processing capability of 2000 times/sec
 

F350

Digital Indicator of 2ch Input Type

 

* Calculation and judgment outputs are available for 2ch input values of strain gauge type sensors.
* Calculation functions (ch1+ch2, ch1-ch2, |ch1-ch2|, High select, Low select)
* 9 points of judgment outputs are equipped.
* Sampling speed as high as 3000 times/sec on each channel
* Equivalent input calibration function enables calibration only by key-inputting the Rated Value of a sensor.
* Analog monitor output
 

F320

Compact DIN 96 x 48 mm Size Digital Indicator

* Convenient DIN 96 x 48 mm size that can be easily mounted on control panel
* Standard built-in RS485 (Modbus-RTU communication protocol)
* High-speed digital processing capability of 2000 times/sec
* Equivalent input calibration function allows calibration only by key-inputting the Rated Value of a sensor.
 
F340A

Compact Square DIN 96 Type Digital Indicator

 

* Analog peak hold function providing high-speed peak hold
* Digital zero function for one-touch zeroing of indicated value
* Compact square DIN 96 size
* High-speed HI/LO limit comparison function
* Equivalent input calibration function enables calibration only by key-inputting the Rated Value of a sensor.
 

F130

Loadcell Interface for OMRON SYSMAC CJ1

* Direct connection to OMROM SYSMAC CJ1 network system
* High-speed sampling of 3000 times/sec
* Completely seamless communication between CJ1 and F130
* System development time is reduced and maintenance management modifications and servicing are easy
* With greatly simplified inter-equipment wiring, cost advantages can be expected.
 
F490A

Portable Digital Indicator with Recording Function

* Lightweight design of 290g for portable use
* Measurement data is recorded in CSV format in its internal memory.
* Recorded data can be referred to and copied via USB interface.
* Various display modes such as graphic display and recorded data display prepared
* Multi-calibration function that allows four calibration values to be stored and read
* 4 types of Hold functions can set the data observation range.
 

 

Copyright © Warytech 2006. All rights reserved.